Product Description

The Newcrom R1 HPLC column 150x4.6mm, 5µm, is a reversed phase with particularly low silanol activity and thus the only phase in the range without a charged group. Its speciality is alkali resistance: the recommended range extends from pH 1.0 to 10.0. This is demonstrated by a continuous test at pH 10.6 for more than fifteen hours. Almost two hundred injections of a mixture of neutral, basic and acidic substances did not noticeably change the retention. For storage between measurement series, an acidic mobile phase is nevertheless recommended, for example about 0.1 percent phosphoric acid or formic acid in equal parts acetonitrile and water.

Features and Benefits

  • Ion exchange and reverse-phase separation in a single phase
  • Mirrored acidic and basic versions
  • Two chain lengths per charge type
  • Low buffer concentration is sufficient
  • Suitable for LC-MS and preparative separations

Additional Notes

Newcrom is a mixed-mode series in which the charged group is not embedded in the chain but is located at its end. This distinguishes it from the embedded groups in other Sielc series and has a practical consequence: The charge is readily accessible to the analyte, so even a low buffer concentration is sufficient for effective ion exchange. Less buffer means less stress on the ion source, which is why these columns are well-suited for mass spectrometry. Four of the six phases form a grid based on two decisions. The first concerns the charge: The letter A stands for an acidic, i.e., negatively charged group that retains weak bases via cation exchange and repels acids via ion exclusion. The letter B stands for a basic, i.e., positively charged group, where the opposite is true. The second decision concerns the chain length, represented by the appended H: without H, the group is at the end of a long chain; with H, it is at the end of a short one. The long chain results in greater hydrophobic retention, while the short chain places greater emphasis on ionic interactions. In both cases, neutral substances are still retained via the reverse phase, and multiply charged substances benefit particularly. The other two phases fall outside this framework. Newcrom CN2 is a cyano phase without a charged group, while Newcrom R1 is a reverse phase with low silanol activity for operation in basic conditions.

Legal Information

Newcrom is a trademark of SIELC Technologies, Inc., Wheeling, Illinois. The product and phase names mentioned are part of the manufacturer's chromatography portfolio.

Product Specification

Brand Newcrom
Product Type HPLC Column
Length 150 mm
Internal Diameter 4.6 mm
Particle Size 5 µm
Chemistry multi-mode
Chemistry Producers Term R1
Pore Size 100 Å
Endcapping endcapped
Country of Origin United States of America (USA)
Column Type Analytical Column
Hardware Material Stainless Steel
Hardware Type Ready-to-use Column
pH Minimum 1.0
pH Maximum 10.0
Mode of Separation Mixed-mode phases
Technology HPLC
Matrix Silica
Particle Morphology spherical, fully porous