GC COLUMN HI-WAX 0.32MM 0.20UM 50M, UoM: 1 * 1 items

Part Number: HI09-32-020-50
Manufacturer: Hichrom Ltd
|
Delivery Time: approx. 7 days
Excl. 19% taxes, excl. Shipping costs
Packaging unit: 1 pc, Minimum order quantity: 1 pc
Product Line

Questions, MSDS, CoA?

Do you have any questions? Give us a call or send us an email!

Product Description

The HiCap WAX GC capillary column 50mx0.32mm, 0.2µm, uses polyethylene glycol as the stationary phase and is therefore highly polar. Separation is according to the distribution of substances between the film on the capillary wall and the carrier gas.Polyethylene glycol separates mainly via hydrogen bonding, which is why alcohols and other substances with hydroxyl groups are retained considerably more strongly than on siloxane phases.Target analytes are esters, fragrance compounds, flavouring substances, alcohols, aromatic hydrocarbons and fatty acid methyl esters. The separation of aroma and fragrance compounds is documented as an application example.

Features and Benefits

  • Phases ranging from nonpolar to highly polar
  • Cross-linked and bonded packings
  • Low-bleed versions for mass spectrometry
  • Chiral cyclodextrin phases in beta and gamma
  • Application phases based on standardized methods
  • Retention reproducible across batches

Additional Notes

HiCap is Hichrom’s line of capillary columns for gas chromatography. Unlike in liquid chromatography, the stationary phase here is not supported by particles but is instead a thin film coating the inner wall of a quartz capillary. Separation occurs based on the distribution of the substances between this film and the flowing carrier gas. The choice of column depends on the polarity of the phase. Pure dimethylpolysiloxane is nonpolar and separates substances primarily by boiling point; an increasing proportion of phenyl or cyanopropyl groups introduces polar interactions and shifts the order of separation, with polyethylene glycol at the polar end of the spectrum. The suffix “MS” designates versions with particularly low bleeding, which is important when coupled with a mass spectrometer. A special variant is the 5MS2 version, in which arylene groups are incorporated into the polymer backbone; these groups stabilize the structure and slow down the degradation of the phase. The selectivity of this version is nearly identical to that of the standard version.

Legal Information

HiCap is a trademark of Hichrom Limited, Theale near Reading, United Kingdom, a company of the Avantor Group. The product and phase names mentioned are part of the manufacturer's chromatography portfolio.

Product Specification

Brand Hichrom
Product Type GC Column
Length 50 m
Internal Diameter 0.32 mm
Film Thickness [µm] 0.2 µm
Chemistry WAX (WAX MS)
Chemistry Producers Term WAX
USP Class G14, G15, G16
Country of Origin Great Britain
Column Type Capillary Column
Base Material Polyethylene glycol
Temperature Minimum [°C] 250
Mode of Separation Gas Chromatography