MXT-Volatiles Cap. Column 30m 0.53mm ID 3.00um, 2.75inID/3.5inOD Coil without Cage 9 Column Leads

Part Number: RT70922-2732
Manufacturer: Restek
|
Delivery Time: approx. 5 days
Excl. 19% taxes, excl. Shipping costs
Packaging unit: 1 pc, Minimum order quantity: 1 pc
Product Line

Questions, MSDS, CoA?

Do you have any questions? Give us a call or send us an email!

Product Description

The MXT-Volatiles GC metal capillary column 30mx0.53mm, 3µm, applies its stationary phase to the Siltek-treated, and thereby inert, stainless steel wall and is tailored to volatile organic contaminants.It was the first column specifically developed for the thirty-four compounds of the US methods EPA 601, 602 and 624, and quantifies all of their target analytes.It can be operated on a mass spectrometer as well as on a photoionisation detector in series with an electrolytic conductivity detector. The metal capillary makes it suitable for field instruments and process applications.

Features and Benefits

  • Stainless steel capillary instead of quartz glass
  • Siltek treatment renders the metal wall inert
  • Shatterproof for field instruments and process analytics
  • Also suitable for low-volatility substances
  • Fifteen phases plus four PLOT versions

Additional Notes

MXT addresses the only weakness of quartz glass capillaries: their susceptibility to breakage. While this is hardly an issue in the laboratory, it becomes a major concern in field instruments, process GC systems, or instruments with small ovens. Here, the tube is made of stainless steel and is therefore mechanically robust. However, metal is inherently catalytically active and would trap or decompose sensitive substances, which is why the inner wall is treated using the Siltek method. This treatment deposits an inert layer on the metal, allowing the column to combine the strength of steel with the inertness of glass. The second reason for using a metal capillary is high-temperature chromatography, such as for triglycerides or heavy petroleum fractions, where quartz glass reaches its limits. The phases themselves correspond to those of the Rtx series and bear the same numbers, so that a method developed in the laboratory on an Rtx-5 can be transferred to an MXT-5. All columns have a packing diameter of four and a half inches.

Legal Information

MXT is a trademark of Restek Corporation, Bellefonte, Pennsylvania. The product and phase names mentioned are part of the manufacturer's chromatography portfolio.

Product Specification

Brand MXT
Product Type GC Column
Length 30 m
Internal Diameter 0.53 mm
Film Thickness [µm] 3 µm
Chemistry Volatiles
Chemistry Producers Term Volatiles
Country of Origin United States of America (USA)
Column Type Capillary Column
Temperature Minimum [°C] -20
Temperature Maximum [°C] 250/320
Mode of Separation Gas Chromatography