MXT-WAX Cap. Column 30m 0.25mm ID 0.25um, 2.75inID/3.5inOD Coil without cage 9 Column Ends

Part Number: RT70623-2732
Manufacturer: Restek
|
Delivery Time: approx. 5 days
Excl. 19% taxes, excl. Shipping costs
Packaging unit: 1 pc, Minimum order quantity: 1 pc
Product Line

Questions, MSDS, CoA?

Do you have any questions? Give us a call or send us an email!

Product Description

The MXT-WAX GC metal capillary column 30mx0.25mm, 0.25µm, carries a bonded polyethylene glycol as the polar stationary phase on the Siltek-treated stainless steel wall. The oxygen atoms of the chain accept hydrogen bonds, so alcohols, esters and aldehydes are retained significantly more strongly than hydrocarbons of the same boiling point. It is assigned to USP phase classes G14, G15, G16, G20 and G39. Documented are fatty acid methyl esters, abbreviated FAMEs, as well as flavouring substances, essential oils, amines, solvents, the xylene isomers and the EPA 603 method for acrolein and acrylonitrile. In addition, the purity testing of chemicals and the analysis of alcoholic beverages are mentioned.

Features and Benefits

  • Stainless steel capillary instead of quartz glass
  • Siltek treatment renders the metal wall inert
  • Shatterproof for field instruments and process analytics
  • Also suitable for low-volatility substances
  • Fifteen phases plus four PLOT versions

Additional Notes

MXT addresses the only weakness of quartz glass capillaries: their susceptibility to breakage. While this is hardly an issue in the laboratory, it becomes a major concern in field instruments, process GC systems, or instruments with small ovens. Here, the tube is made of stainless steel and is therefore mechanically robust. However, metal is inherently catalytically active and would trap or decompose sensitive substances, which is why the inner wall is treated using the Siltek method. This treatment deposits an inert layer on the metal, allowing the column to combine the strength of steel with the inertness of glass. The second reason for using a metal capillary is high-temperature chromatography, such as for triglycerides or heavy petroleum fractions, where quartz glass reaches its limits. The phases themselves correspond to those of the Rtx series and bear the same numbers, so that a method developed in the laboratory on an Rtx-5 can be transferred to an MXT-5. All columns have a packing diameter of four and a half inches.

Legal Information

MXT is a trademark of Restek Corporation, Bellefonte, Pennsylvania. The product and phase names mentioned are part of the manufacturer's chromatography portfolio.

Product Specification

Brand MXT
Product Type GC Column
Length 30 m
Internal Diameter 0.25 mm
Film Thickness [µm] 0.25 µm
Chemistry WAX (WAX MS)
Chemistry Producers Term WAX
USP Class G14, G15, G16, G20, G39
Country of Origin United States of America (USA)
Column Type Capillary Column
Base Material Polyethylene glycol
Temperature Minimum [°C] 40
Temperature Maximum [°C] 250/260
Mode of Separation Gas Chromatography