Rxi-5Sil MS Cap. Column 30m 0.25mm ID 0.25um Old Style Cage

Part Number: RT13623-151
Manufacturer: Restek
|
Delivery Time: approx. 5 days
Excl. 19% taxes, excl. Shipping costs
Packaging unit: 1 pc, Minimum order quantity: 1 pc
Product Line

Questions, MSDS, CoA?

Do you have any questions? Give us a call or send us an email!

Product Description

The Rxi-5Sil MS GC capillary column 30mx0.25mm, 0.25µm, contains a low-polarity polysiloxane phase in which phenyl groups are not only pendant side chains but are incorporated into the polymer backbone. This is indicated by the Sil MS designation. This incorporation increases thermal stability, reduces column bleed and makes the phase less prone to oxidation. Combined with thorough deactivation of the capillary inner wall, this results in a highly inert column for mass spectrometry. Mentioned are semi-volatile compounds, polycyclic aromatic hydrocarbons, chlorinated hydrocarbons, phthalates, phenols, amines, chlorinated and organophosphorus pesticides as well as pharmaceuticals. A variant with an integrated Integra-Guard pre-column is listed.

Features and Benefits

  • Tested for very low column bleed
  • Fourteen phases ranging from nonpolar to moderately polar
  • Designed for coupling with mass spectrometers
  • High inertness toward reactive compounds
  • Optionally available with an integrated Integra-Guard precolumn

Additional Notes

Rxi is the capillary column series for mass spectrometry. It differs from the broader Rtx series not primarily in terms of phase composition, but rather in what happens to the polymer and the inner wall of the capillary before the column is shipped. Each column is tested for column bleeding—that is, the amount of phase material that detaches during heating. This material reaches the detector and increases the background noise there; while this is hardly a problem for a flame ionization detector, it directly worsens the detection limit in a mass spectrometer. Added to this is the issue of inertness: active sites on the inner wall of the capillary trap sensitive substances, resulting in skewed peaks or losses; this is why deactivation is carried out particularly thoroughly here.

Legal Information

Rxi is a trademark of Restek Corporation, Bellefonte, Pennsylvania. The product and phase names mentioned are part of the manufacturer's chromatography portfolio.

Product Specification

Brand Rxi
Product Type GC Column
Length 30 m
Internal Diameter 0.25 mm
Film Thickness [µm] 0.25 µm
Chemistry 5 (5HT, 5MS)
Chemistry Producers Term 5Sil MS
Country of Origin United States of America (USA)
Column Type Capillary Column
Base Material Silphenylene methylpolysiloxane
Temperature Minimum [°C] -60
Temperature Maximum [°C] 320/350
Mode of Separation Gas Chromatography