Checkout using your account
Checkout as a new customer
Creating an account has many benefits:
Questions, MSDS, CoA?
Do you have any questions? Give us a call or send us an email!


The Rtx-5 GC capillary column 15mx0.53mm, 1.5µm, contains diphenyldimethylpolysiloxane with five percent phenyl groups and is therefore low-polarity. From the polymer catalyst residues and low-molecular-weight fragments are removed so that the molecular weight distribution remains narrow and column bleed is very low. It is regarded as the most widely used phase in gas chromatography and is assigned to USP phase classes G27 and G36.Medicinal products, solvent impurities, pesticides, hydrocarbons, PCB congeners, essential oils and semi-volatile substances are documented. The variant is also available with an integrated Integra-Guard guard column.
Rtx is Restek’s basic series of GC capillary columns and, with thirty-four phases, is also the broadest. The designation stands for “Crossbonded” and describes cross-linked and mostly bonded phases. It identifies the columns housed in quartz glass capillaries and distinguishes them from the three sister series. Rxi features the same design with an additional test for very low column bleed; MXT features the same phases in a stainless steel capillary; and Rt features specialty phases outside this range. What sets the series apart lies less in the individual phases than in three characteristics shared by all models. The first is the polymer preparation. Catalyst residues and low-molecular-weight fragments are removed from it before it comes into contact with the capillary wall, resulting in a narrow and uniform molecular weight distribution. This leads to the very low column bleed for which the series is known, and with it, a stable baseline and a long service life. The second is the range. The series ranges from pure dimethylpolysiloxane to cyanopropyl phases, covering the entire polarity scale, so that a second column within the same series can be found to confirm a result. The third is the Integra-Guard design, in which the pre-column and separation column are manufactured as a single piece, eliminating the connection between the two as a source of error.
Rtx is a trademark of Restek Corporation, Bellefonte, Pennsylvania. The product and phase names mentioned are part of the manufacturer's chromatography portfolio.
| Brand | Rtx |
|---|---|
| Product Type | GC Column |
| Length | 15 m |
| Internal Diameter | 0.53 mm |
| Film Thickness [µm] | 1.5 µm |
| Chemistry | 5 (5HT, 5MS) |
| Chemistry Producers Term | 5 |
| USP Class | G27, G36 |
| Country of Origin | United States of America (USA) |
| Column Type | Capillary Column |
| Base Material | 5% Phenyl 95% methylpolysiloxane |
| Temperature Minimum [°C] | -60 |
| Temperature Maximum [°C] | 310/330 |
| Mode of Separation | Gas Chromatography |