Checkout using your account
Checkout as a new customer
Creating an account has many benefits:
Questions, MSDS, CoA?
Do you have any questions? Give us a call or send us an email!


The IAM Fast-Screen Mini Column 10x3.0mm, 10µm is a short column for rapid screening of many drug candidates for their interaction with phospholipids. In a screening the resolution of individual peaks is not important, but rather a single characteristic value per substance in the shortest possible time, which is why a short column suffices here and the runtime accordingly decreases. It is supplied as a set, and there is a replacement set with six columns for continuous operation. Calibration with the associated mixture is also envisaged for this version so that the values remain comparable.
IAM stands for Immobilized Artificial Membrane. This series therefore serves a different purpose than any other chromatography column. Its primary function is not separation, but rather measurement—specifically, measuring how well an active substance penetrates a cell membrane. This is facilitated by the stationary phase, phosphatidylcholine—the very phospholipid that makes up the majority of a cell’s membrane. The molecules are covalently bound to aminopropyl silica gel via an amide bond and form a monolayer on its surface. Because this layer mimics the conditions in a real membrane, an analyte behaves within it similarly to how it would when passing through a cell wall, and its retention time serves as a measure of this interaction. This is the crucial difference from the determination of the partition coefficient in octanol and water, which measures only lipid solubility. However, a membrane is not a droplet of fat; rather, it has an ordered structure and is charged at its surface, which is why the two methods yield different results. To ensure that the values obtained in this way remain comparable across laboratories, a calibration mixture with specified values is provided. Three versions are available, which differ in how the amino groups—which remain on the silica gel after the phospholipid has bound—are handled.
The product and phase names listed are part of the chromatography portfolio of Regis Technologies, Inc., Morton Grove, Illinois.
| Brand | IAM |
|---|---|
| Product Type | HPLC Column Kit |
| Length | 10 mm |
| Internal Diameter | 3.0 mm |
| Particle Size | 10 µm |
| Chemistry | multi-mode |
| Country of Origin | United States of America (USA) |
| Column Type | Analytical Column |
| Hardware Type | Ready-to-use Column |
| pH Minimum | 2.5 |
| pH Maximum | 7.5 |
| Temperature Minimum [°C] | 20 |
| Temperature Maximum [°C] | 60 |
| Pressure Stability | 413 bar |