IAM Drug Screen Calibration Mixture (10x1 mL)

Part Number: 1-774015-300
Manufacturer: Regis Technologies
|
Delivery Time: approx. 6 days
Excl. 19% taxes, excl. Shipping costs
Packaging unit: 10 pcs, Minimum order quantity: 1 pc
Product Line

Questions, MSDS, CoA?

Do you have any questions? Give us a call or send us an email!

Product Description

The IAM Drug Screen calibration mixture 10x1ml is not a mobile phase but the reagent used to place the measurements from an IAM column onto a common scale. For this purpose it contains substances whose reference values have been determined beforehand. If their retention times are plotted against these predetermined values, a straight line is obtained that can be used to convert the retention time of any subsequent substance into the same reference value. Calibration is intended before each measurement series so that values remain comparable between different laboratories. Which substances the mixture contains is proprietary.

Features and Benefits

  • The phospholipid layer mimics the cell membrane
  • Measures membrane permeability rather than just lipophilicity
  • Covalently bound and therefore stable
  • Calibration mixture for comparable measurement results
  • Also suitable for purifying membrane proteins

Additional Notes

IAM stands for Immobilized Artificial Membrane. This series therefore serves a different purpose than any other chromatography column. Its primary function is not separation, but rather measurement—specifically, measuring how well an active substance penetrates a cell membrane. This is facilitated by the stationary phase, phosphatidylcholine—the very phospholipid that makes up the majority of a cell’s membrane. The molecules are covalently bound to aminopropyl silica gel via an amide bond and form a monolayer on its surface. Because this layer mimics the conditions in a real membrane, an analyte behaves within it similarly to how it would when passing through a cell wall, and its retention time serves as a measure of this interaction. This is the crucial difference from the determination of the partition coefficient in octanol and water, which measures only lipid solubility. However, a membrane is not a droplet of fat; rather, it has an ordered structure and is charged at its surface, which is why the two methods yield different results. To ensure that the values obtained in this way remain comparable across laboratories, a calibration mixture with specified values is provided. Three versions are available, which differ in how the amino groups—which remain on the silica gel after the phospholipid has bound—are handled.

Legal Information

The product and phase names listed are part of the chromatography portfolio of Regis Technologies, Inc., Morton Grove, Illinois.

Product Specification

Amount 1 ml
Brand IAM
Product Type Organic Standards
Chemistry multi-mode
Country of Origin United States of America (USA)