The IAM.PC.DD2 HPLC column 100x3.0mm, 10µm, carries phosphatidylcholine, covalently bound to silica gel, and is the version for the determination of membrane permeability of active pharmaceutical ingredients. As phospholipids constitute the main component of tissues and cells, the interaction of an active substance with them contributes significantly to its distribution in the body.This interaction is measured by the retention time, which can be converted into a characteristic value.To ensure the values remain comparable between instruments and laboratories, calibration with the corresponding mixture is performed before each series of measurements.The application is described for rapid biomimetic screening of drug candidates.
IAM stands for Immobilized Artificial Membrane. This series therefore serves a different purpose than any other chromatography column. Its primary function is not separation, but rather measurement—specifically, measuring how well an active substance penetrates a cell membrane. This is facilitated by the stationary phase, phosphatidylcholine—the very phospholipid that makes up the majority of a cell’s membrane. The molecules are covalently bound to aminopropyl silica gel via an amide bond and form a monolayer on its surface. Because this layer mimics the conditions in a real membrane, an analyte behaves within it similarly to how it would when passing through a cell wall, and its retention time serves as a measure of this interaction. This is the crucial difference from the determination of the partition coefficient in octanol and water, which measures only lipid solubility. However, a membrane is not a droplet of fat; rather, it has an ordered structure and is charged at its surface, which is why the two methods yield different results. To ensure that the values obtained in this way remain comparable across laboratories, a calibration mixture with specified values is provided. Three versions are available, which differ in how the amino groups—which remain on the silica gel after the phospholipid has bound—are handled.
The product and phase names listed are part of the chromatography portfolio of Regis Technologies, Inc., Morton Grove, Illinois.
| Brand | IAM |
|---|---|
| Product Type | HPLC Column |
| Length | 100 mm |
| Internal Diameter | 3.0 mm |
| Particle Size | 10 µm |
| Chemistry | multi-mode |
| Chemistry Producers Term | PC.DD2 |
| Country of Origin | United States of America (USA) |
| Column Type | Analytical Column |
| Base Material | Phosphatidylcholine |
| Hardware Material | Stainless Steel |
| Hardware Type | Ready-to-use Column |
| pH Minimum | 2.5 |
| pH Maximum | 7.5 |
| Temperature Minimum [°C] | 20 |
| Temperature Maximum [°C] | 60 |
| Technology | HPLC |
| Matrix | Silica |
| Particle Morphology | fully porous |
| Pressure Stability | 413 bar |