MCl Gel Ion exchange column CK08EH, 300x7.8mm LxID 9µm

Part Number: MCL-0-010-08
Manufacturer: Mitsubishi Chemical
|
Delivery Time: approx. 10 days
Excl. 19% taxes, excl. Shipping costs
Packaging unit: 1 pc, Minimum order quantity: 1 pc
Product Line

Questions, MSDS, CoA?

Do you have any questions? Give us a call or send us an email!

Product Description

The MCI GEL CK08EH HPLC column 300x7.8mm, 9µm, is the hydrogen form of the sulfonated polystyrene exchanger and operates according to the principle of ion exclusion. Organic acids are undissociated in the acidic eluent, penetrate into the resin and are retained, while dissociated and inorganic ions are repelled by the resin and elute early. A percent phosphoric acid is commonly used as eluent, the USP class is L17. Separated are organic acids, chlorinated acetic acids, alcohols, sugar alcohols and amino sugars.

Features and Benefits

  • Polymer particles
  • Exchangers available in multiple counterion forms
  • Reverse-phase columns across the entire pH range
  • Ligand exchange for sugars and isomers
  • A matching pre-column for each main column
  • Multiple pack sizes with USP classification

Additional Information

MCI GEL is based on Mitsubishi’s ion-exchange and adsorbent resins, which are marketed under the names Diaion and Sepabeads. The packing materials are entirely polymer-based—typically polystyrene cross-linked with divinylbenzene or polymethacrylate—and therefore do not require the silica gel matrix that would otherwise limit the pH range to higher values. The designations follow a fixed system. After the “C,” “K” stands for a cation exchanger and “A” for an anion exchanger; the following number indicates the degree of cross-linking as a percentage of divinylbenzene; and the letter after that denotes the particle size. An additional suffix letter indicates the counterion form: C for calcium, H for hydrogen, and S for silver; without this suffix, the column is in the sodium form. A suffix G denotes the precolumn, and PC denotes the upstream protective column in the eluent path.

Legal Information

MCI GEL, Diaion, and Sepabeads are trademarks of Mitsubishi Chemical Corporation, Tokyo. The product and phase names mentioned are part of the manufacturer's chromatography portfolio.

Product Specification

Brand MCl Gel
Product Type HPLC Column
Length 300 mm
Internal Diameter 7.8 mm
Particle Size 9 µm
Chemistry Producers Term CK08EH
USP Class L17
Country of Origin Japan
Column Type Analytical Column
Base Material Styrene-divinylbenzene
Hardware Material Stainless Steel
Hardware Type Ready-to-use Column
pH Minimum 1.0
pH Maximum 7.0
Mode of Separation Ion Exclusion Chromatography
Technology HPLC
Matrix Polymer
Particle Morphology spherical, fully porous
Counter Ion Hydrogen (H+)
Crosslinkage 8 %

Support - Downloads