Osaka-Soda C18 KG Series

Osaka-Soda's Capcell PAK C18 KG series is based on an improved silica gel, which has been coated with a new polymer coating. This new polymer coating achieves a pH stability of 1.0 - 12.0. As a result, these phases are used in applications with strongly acidic or alkaline conditions. Due to the high pH stability, these columns can also be used as a replacement for other hybrid phases.

Products

Price
Length
Internal Diameter
Particle Size
Chemistry Producers Term
Hardware Material
Technology
Pressure Stability
Sort By sort-descending

Items 1-10 of 43

Page
per page
OS-95095
€832.00 €665.60
OS-95094
€766.00 €612.80
OS-95093
€750.00 €600.00
OS-85104
€612.00 €489.60
OS-85103
€602.00 €481.60
OS-85102
€585.00 €468.00
OS-85101
€580.00 €464.00
OS-85318
€530.00 €424.00
OS-85317
€439.00 €351.20
OS-85316
€399.00 €319.20
Sort By sort-descending

Items 1-10 of 43

Page
per page

Technical Data

Capcell-Pak KG Series

Phase name

Modification

Particle size

Pore size

End-capping

C-content

USP

Surface area

pH range

Tmax

Capcell PAH C18 KG

C18

2, 3, 5 µm

100 Ã…

new Polymer coating

17 %C

L1

320 m²/g

1.0 - 12.0

N/A

What characterises the Osaka-Soda C18 KG column?

  • low column bleed allows the use of an NQAD detector or MS/MS detection

Peak identities

1 BIGCHAP

Test conditions

HPLC column: Capcell PAK C18 KG S3, 150x4.6mm, 3µm

Mobile phase: water/acetonitrile 70/30

Flow rate: 1.0 mL/min

Temperature: 40°C

Injection volume: 5 µL

  • Excellent peak shape for basic compounds under acidic, neutral and basic conditions

Test conditions

HPLC column: Capcell PAK C18 KG S3, 150x4.6mm, 3µm

Mobile phase: (pH 2) 20 mmol/L phosphate buffer/acetonitrile 40/60

(pH 7) 20 mmol/L phosphate buffer/acetonitrile 40/60

(pH 11.5) 20 mmol/L Na2B4O7* 10 H2O/acetonitrile 40/60

Flow rate: 1.0 mL/min

Temperature: 30 °C

Detection: UV 254 nm

Injection volume: 5 µL

Sample: Amitriptyline (100 µg/mL)


When will you benefit from the Osaka-Soda C18 KG Series?

  • Better peak shape for basic compounds under acidic conditions compared to hybrid columns

Peak identities

1. blonanserin

Test conditions

Column dimension: 150x4.6mm

Mobile phase: 0.1 vol% formic acid/methanol 30/70

Flow rate: 1.0 mL/min

Temperature: 40 °C

Detection: UV 254 nm

Sample: Blonanserin (50 µg/mL)

  • higher soil numbers than hybrid materials with smaller particles at higher flow rates

Test conditions

Column dimension: 50x2.1mm

Mobile phase: 20 mmol/L phosphate buffer (KH2PO4/K2HPO4 1/1)/methanol 20/80

Temperature: 40 °C

Detection: UV 220 nm

Injection volume: 1 µL

Sample: Amitriptyline (100 µg/mL)

Conclusion: Osaka-Soda's C18 KG columns show outstanding stability under acidic and basic conditions and can be an alternative to hybrid materials in many applications.

Downloads

Contact Us

Fields marked with * must be filled in

The right column for you - we will be happy to support you individually

Competent consultants are always at your side. Write a message to our consultants, we will get back to you and give you individual support.

You will find:

Application support Application support
Availability and delivery times Availability and delivery times
Price information with individual conditions Price information with individual conditions
Certificates of analysis, MSDS, data sheets Certificates of analysis, MSDS, data sheets